Skip to main content

Front panel software

This page describes the Front Panel Display. Turn the encoder to move; press to select. Every list ends with BACK. Changes stay in sync with the web interface.

The home screen is METERS. After 30 seconds of encoder inactivity the panel returns there. That timeout is separate from the PIN auto-lock.

Meters

Two rows of live bars (−80 to 0 dBFS):

Row Channels
INPUT 1–4 analogue, 5–8 digital
OUTPUT 1–4 speaker outputs
  • A muted output shows a mute symbol and a dim red bar.
  • A bridged pair is drawn cyan. The unused half of the pair mirrors the master.

Press the encoder to open the main menu.

Main menu

METERS · INPUTS · ZONES · OUTPUTS · STATUS · SETTINGS

Zones in this menu are the same four objects as Zones in the browser.

A trailing * on an input, zone, or output means that channel has advanced settings (user EQ from the web interface). A bridged output is labelled OUTPUT n - BRIDGED (and * if it also has advanced settings).

The panel lists channels as ANALOGUE 1–4, DIGITAL 1–4, ZONE 1–4 and OUTPUT 1–4. Custom names from the web interface are not shown on this display.

Inputs

Channel Items
ANALOGUE 1–4 GAIN, SENSITIVITY (+12dBu, +28dBu, +4dBu, −10dBV), RESET ADVANCED
DIGITAL 1–4 TRIM

There is no EQ editor on the panel.

Zones

LEVEL, SOURCE, RESET ADVANCED.

Source list: ANALOGUE 1–4, DIGITAL 1–4, MIX 1–4, GENERATOR.

Outputs

GAIN, SOURCE, LPF TYPE, LPF FREQ., HPF TYPE, HPF FREQ., DELAY, POLARITY, PRESET, OUTPUT MODE, MUTE, RESET ADVANCED.

Item Values
Source ZONE 1–4
Polarity NORMAL, INVERTED
Output mode OFF, NORMAL, BRIDGE
Mute OFF, ON
Delay milliseconds
Crossover type OFF, 1ST, BE-12, BW-12, LR-12, BE-18, BW-18, LR-18, BE-24, BW-24, LR-24, BE-48, BW-48, LR-48

PRESET opens a browser: SELECT SERIES → model → preset. The first series list also has FLAT (no speaker processing).

Status

Page Fields
DEVICE NAME, MODEL, SERIAL, TEMP, FW PKG, FW CORE, FW AUX, FW UI, FW PANEL, LIBRARY, LIB VER
ETHERNET STATUS, MAC, IP, SUBNET
WIFI STATUS, MAC, SSID, IP, SUBNET
WIFI AP STATUS, MAC, SSID, IP, SUBNET
EXPANSION TYPE (NONE or DANTE 4X4), MUTE, CLOCK, SAMPLE RATE, MAC, IP, SUBNET

IP and subnet show N/A when that interface is down. Expansion clock reads DISABLED, MASTER INT., MASTER EXT., SLAVE SYNC, or SLAVE NO SYNC.

WIFI AP shows the SSID, not the password.

Settings

FAN · POWER · GENERATOR · LOCK · RESET

Item Options
Fan CURVE STANDARD, QUIET, PERFORMANCE
Power MODE AUDIO, AUDIO (ECO), AUDIO (DIGITAL), TRIGGER (ECO), TRIGGER, NETWORK
Power MUTE / STANDBY minutes (0 = off)
Generator LEVEL, SOURCE (WHITE NOISE or SINE), SINE FREQ.
Reset CONFIRM — wipes user configuration and restarts. The panel shows Resetting Device / The Amplifier is resetting, please wait...

PIN lock

SETTINGS → LOCK

Item Behaviour
SET PIN Four digits. Turn to set digit, press to confirm. Enter once (ENTER PIN), then again (CONFIRM PIN). A mismatch shows PIN MismatchThose PINs don't match - try again.
CLEAR PIN Needs the current PIN. Also clears the lock and auto-lock.
AUTO-LOCK OFF, 30 SEC, 1 MIN, 5 MIN, 15 MIN, 30 MIN, 1 HR of encoder inactivity
LOCK NOW Needs a PIN. Returns to meters. The lock overlay appears on the next encoder press.

Until a PIN is set, lock is not available (No PIN Set / Set a PIN first.).

The lock overlay is titled LOCKED. Turning the encoder does nothing until you press, then enter the four digits. A wrong PIN shows Incorrect PIN. Unlock is remembered until you lock again or auto-lock expires.

The web interface is not affected by the panel lock.

Reset Advanced

Confirm NO / YES.

  • Input or output: turns all user EQ bands off and clears the * flag
  • Zone: clears the flag only (zones have no user EQ)

It does not remove a speaker preset, mute, delay, or names.

Firmware update

While the amplifier is flashing, the display shows FIRMWARE UPDATE, a progress bar, Updating firmware..., and Do not power off. The encoder is ignored until the update finishes.